Digital Water Magnetic Flowmeter, Electromagnetic Flow Meter
Basic Info.
Model NO.:magnetic flowmeter | Main Application:Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas |
Sensor:Clamp-on/External | Application:Industrial Production |
Type:Magnetic Flowmeter, | Measuring Media:Conductive Liquid and Slurry |
Measurement Object:Closed Pipeline | Certification:JIS, DIN, ANS, GB, CE, UL, RoHS, SGS, ISO |
Package:Wooden Case or Carton | Specification:CE, ROHS, SGS, GMP |
Trademark:Tianjin U-ideal Instrument | Origin:Tianjin, USA |
Accuracy.:± 0.20% of Reading Plus Zero Stability | Repeatability:± 0.1% |
Max Fluid Velocity:10 M/S | Housing Material:Acrylic Painted Carbon Steel, Optiona |
Line Sizes:1 to 16 Inches | HS Code:90261000 |
Production Capacity:50000PCS/Year |
Product Description
1.Introduction
Intelligent KDLD low cost magnetic water flow meter measuring tool / instrument is manufactured with the modern technology of electromagnetic flow, the measuring principle of which is based on the electromagnetic induction law of Farady. It is mainly used tomeasure the volume flow of conducting liquid and slurry in closed pipeline, applicable to industries like chemical, power supply, metallurgical mine, oil, water supply and drainage, paper making, pharmaceutical, food, etc..
2. Features
a) the measurement is not affected by the density, viscosity, temperature, pressure and electroconductibility of fluid;
b) there are no obstacles or loss of pressure in the measuring pipe, low requirements for straight pipe;
c) the nominal diameter is from DN3 to DN3000 for this series. Multiple choices are available for the liner of converter and the material of electrode;
d) adopt a novel way of excitation, low power consumption, stable zero point and high accuracy. The flow rangeability is up to
3. Specifications
Item | Compact type | Remote type | ||||
Flange connection | Inserted type | Threaded connection | Flange connection | Inserted type | Threaded connection | |
Caliber(mm) | 15~3000 | 125~3000 | 10~25 | 15~3000 | 125~3000 | 10~25 |
Pressure(MPa) | 0.6,1.0,1.6,4.0 | |||||
Accuracy | ±0.5%, ±0.3%(±0.2% available for special order) | |||||
Applicable medium | Conductive liquid and slurry | |||||
Medium Temperature | ≤150°C | |||||
Medium Conductivity | ≥5μS/cm | |||||
Medium Velocity | ≤15 m/s | |||||
Ambient | Temperature:-25°C~+60°C, Humidity: 5%~90% | |||||
Liner Material | DN10mm~32mm: Polytetrafluoroethylene(F4), Polyurethane; | |||||
Electrode Material | Mo-containing stainless steel, Hastelloy B, Hastelloy C, Titanium alloy, Tantalum alloy, Platinum-iridium alloy, Stainless steel-coated tungsten carbide | |||||
Electrode Type | Fixed type(DN150~DN2600); Blade type(DN300~DN1600) | |||||
Flange Material | SS, CS | |||||
Communication | RS485, RS232, HART, Modbus, Profibus-DP | |||||
Signal Output | Analog 4-20mA, isolated, load resistor≤750Ω | |||||
Power Supply | AC 85-265V, 45-63Hz, power≤20W; | AC 85-265V, 45-63Hz, power≤20W; | ||||
Display | LCD display with back light. | Intelligent flow totalizer display. | ||||
Protection Grade | IP65 | IP65, IP67, IP68 | ||||
Explosion- | ExdmIICT4, mdIIBT4 | non |