Electromagnetic Flowmeter Rosemount
Rosemount Magnetic ;Flowmeter Supplier ;
Basic Info.
Model NO.:8700 | Accuracy:0.5% |
Main Application:Water, Wastewater, Corrosive Liquid/Gas | Size:Dn15-2000 |
Sensor:Tube/Flange | Application:Industrial Production |
Type:Electromagnetic Flow Meter | Measuring Media:Liquid |
Measuring Principle:Electrical Principles | Certification:GB, CE, SGS, ISO |
Package:Carton | Trademark:GN |
Origin:China | Medium:10-1000 |
Flow Range:0.16-25000 M³/H | Connection:Flange |
Output:Pulse/4-20mA | Lining Material:PTFE/Rubber |
Electrode Material:Ss316 | Body Material:Carbon Steel/Ss304 |
Power Supply:220V/24V/Lithium Battery | Pressure:10bar |
Type and IP Code:Integrated Type IP65, Remote Type IP68 | HS Code:9026100000 |
Production Capacity:5000PCS/Month |
Product Description
; ;Electromagnetic FlowmeterWorking principleIts measuring principle bases on Faraday electromagnetic induction law:When the liquid flow through the measuring pipe which all around magnetic field, the two vertical direction will have the induced electromotive force which is proportional with the mean velocity of stream.Flowmeter consists of sensor and converter. Converter transfer field current to inner loop of the sensor to engender magnetic field. Conductivity liquid flow through the measuring pipe and get induced force because of cutting magnetic line. By then the electrode around the pipe wall incept induced force and transfer them to converter through signal wire. Converter filer induced force, spread, calculate and exchange them into proportional standard current signal and frequency signal. ;Brief ; ;introduction1.it ;can ;measure ;all ;kinds ;of ; ;electronic ;conductivity ;liquid, ;such ;as ;corrosive ;liquid ;, ;mud ;and ;slurry ;,water ;etc. ;2.The ;result ;cannot ;be ;affected ;by ;temperature, ;pressure, ;viscosity ;and ;dens ity.3.Flow ;sensor ;and ;intelligent ;converter ;compact ;or ;separately ;composes ;a ;com plete ;flowmeter. ;
;Main ;features1.No ;move ;assembly, ;no ;abrasion ;2.Measuring ;range ;rate: ;1:1003.No ;flow ;enhance ;equipment4.Suits ;for ;various ;of ;electronic ;conductivity ;liquid5.No ;affect ;from ;temperature, ;viscosity, ;pressure ;and ;density6.Anti- corrosion7.Measure ;both ;to ;and ;reverse ;flow8.Huge ;display, ;easy ;operate9.Long- term ;EEPROM ;to ;save ;data ;when ;lose ;power10.Support ;MODBUS/HART ;communication ;protocol11.Wide ;working ;volts ;range12.Self ;diagnose ;Series of products
Production line
Installation
Payment Terms ; ;1.Loading Port: Shanghai China2. ;Samples Leading Time: 3-7 working ;days3. ;Delivery Time: Within 7-15 days after payment4.Payment: ; T/T, Western Union, Paypal ; ;After-sales serviceWe promise to deliver the following after-sales service:1. Warranty: The warranty period is 12 months starting from the shipping date;2. Customers will enjoy free repair services for failures found within the warranty due to manufacturing quality;3. For on-site services not arising from manufacturing quality, we shall charge a certain service fee at our discretion based on actual charges incurred such as travel expense; ;4. We provide paid repair services for meter damages not arising from manufacturing quality issues or meter damages not within the scope of warranty. ; ;Parameters: ;
DN | 6mm~~2000mm |
PN | PN6 , PN10 , PN16 , PN25 , PN40 , PN63 , PN100 , PN160 , PN250 , PN420 |
Electrode ;material | 316L |
Lining ;material | PTFE ;or ;customize |
Medium ;tem | 0~70°C , max ;is ; ;180°C |
Shell ;material | carbon ;steel |
Protection ;grade | IP65 , IP67 ; ; ;and ;IP6 |
Connection | all ;applys( eg : BS ;EN1092-1 ) |
;
Converter ;technical ;data
;
Current ;output | 4~20Ma |
Frequency ;output | No ;resource ;pulse : |
Display | With ;8digit ;LCD ;display |
Display ;unit | Instantaneous ;flow ;units ; : m 3 ;/h , ; m 3 ;/m , m 3 ;/s , L/h , L/m , ; L/s , G/h , G/m , G/s . ; Total ;flow ;units: ;m 3 , L , G . |
Communication | MODBUS ;protocol ( optional ) or ;HART ( optional ) |
Protection ;grade | IP65 |
Power ;supply | 220 ;V ;AC ;+20/-60% ; , 50/60 ;Hz , 24 ;V ;DC ;+50/- 25% ; , max.10VA |
EMC ;radiation ;standard | EN ;61326-1 : 2006 ; (BS ;EN50081-1) |
EMC ;anti-jimming ;standard | EN ;61326-1: 2006 ;(BS ;EN50082-1) |
CE ;security | EN ;61010-1 : 2001 |
Ambient ;temp. | 5~55°C |
Ambient ;humi d ity | <85 ;% ;r.h. ;(non ; co n densation) |
; ;
; ;